Üdvözöljük itt: Pirometer.hu! - Hívjon +36 1 4057771

Égőház méret 65

Látható: 1-60 / 101 összesen
12
Mutat oldalanként
Rendezés:
  • BIC 65HB-900/935-(34)EP

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 900 mm steel tube from furnace flange
    • 935 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
    • For pot burner housing
  • BIC 65RB-1000/1035-(37)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 1000 mm steel tube from furnace flange
    • 1035 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
  • BIC 65HB-700/735-(34)EP

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 700 mm steel tube from furnace flange
    • 735 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
    • For pot burner housing
  • BIC 65HB-800/835-(34)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 800 mm steel tube from furnace flange
    • 835 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
  • BIC 65RB-800/835-(37)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 800 mm steel tube from furnace flange
    • 835 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
  • BIC 65RB-550/585-(37)EP

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 550 mm steel tube from furnace flange
    • 585 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
    • For pot burner housing
  • BIC 65HB-700/735-(34)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 700 mm steel tube from furnace flange
    • 735 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
  • BIC 65RB-700/735-(37)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 700 mm steel tube from furnace flange
    • 735 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
  • BIC 65HBL-400/435-(86)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • Lance
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 86
    • Constr. stage E
  • BIC 65HB-500/635-(34A)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 500 mm steel tube from furnace flange
    • 635 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Burner head: heat-resistant
    • Constr. stage E
  • BIC 65HB-600/635-(34)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 600 mm steel tube from furnace flange
    • 635 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
  • BIC 65RB-600/635-(37)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 600 mm steel tube from furnace flange
    • 635 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
  • BICA 65HB-550/685-(34A)DR

    Burner for gas, with aluminium housing
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 550 mm steel tube from furnace flange
    • 685 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Burner head: heat-resistant
    • Constr. stage D
    • For annular excess air burner housing
  • BIC 65HBL-300/335-(86)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • Lance
    • 300 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 86
    • Constr. stage E
  • BIC 65HB-500/535-(34)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 500 mm steel tube from furnace flange
    • 535 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
  • BIC 65HM-350/485-(72A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 350 mm steel tube from furnace flange
    • 485 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BIC 65RB-400/435-(37)EB

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
    • With secondary air holes
  • BIC 65RB-350/385-(37)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 350 mm steel tube from furnace flange
    • 385 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
  • BIC 65HBL-200/235-(86)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • Lance
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 86
    • Constr. stage E
  • BIC 65RBL-200/235-(82)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • Lance
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 82
    • Constr. stage E
  • BIC 65RML-200/235-(83)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For propane, propane/butane, butane (with mixer)
    • Lance
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 83
    • Constr. stage E
  • BIC 65HB-400/435-(34)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
  • BIC 65HD-400/435-(98)F

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For town gas
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 98
    • Constr. stage F
  • BIC 65HM-400/435-(72)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Constr. stage E
  • BIC 65RB-400/435-(37)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
  • BIC 65RD-400/435-(38)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For town gas
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 38
    • Constr. stage E
  • BIC 65RM-400/435-(71)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For propane, propane/butane, butane (with mixer)
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 71
    • Constr. stage E
  • BIC 65HB-250/385-(34A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 250 mm steel tube from furnace flange
    • 385 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BIC 65HM-250/385-(72A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 250 mm steel tube from furnace flange
    • 385 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BIC 65HB-200/335-(34A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 200 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BIC 65HM-200/335-(72A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 200 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BIC 65MB-0/35-(104)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • For low NOx operation menox
    • For natural gas
    • 0 mm steel tube from furnace flange
    • 35 mm furnace flange-front edge of burner disk
    • Code of burner head 104
    • Constr. stage E
  • BIC 65HBL-100/135-(86)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • Lance
    • 100 mm steel tube from furnace flange
    • 135 mm furnace flange-front edge of burner disk
    • Code of burner head 86
    • Constr. stage E
  • BIC 65HB-300/335-(34)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 300 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
  • BIC 65HD-300/335-(98)F

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For town gas
    • 300 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 98
    • Constr. stage F
  • BIC 65HM-300/335-(72)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 300 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Constr. stage E
  • BIC 65RB-300/335-(37)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 300 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
  • BIC 65RD-300/335-(38)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For town gas
    • 300 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 38
    • Constr. stage E
  • BIC 65RM-300/335-(71)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For propane, propane/butane, butane (with mixer)
    • 300 mm steel tube from furnace flange
    • 335 mm furnace flange-front edge of burner disk
    • Code of burner head 71
    • Constr. stage E
  • BIC 65HB-150/285-(34A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 150 mm steel tube from furnace flange
    • 285 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BIC 65HM-150/285-(72A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 150 mm steel tube from furnace flange
    • 285 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BICA 65HB-350/485-(34A)DR

    Burner for gas, with aluminium housing
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 350 mm steel tube from furnace flange
    • 485 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Burner head: heat-resistant
    • Constr. stage D
    • For annular excess air burner housing
  • BIC 65HB-100/235-(34A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 100 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BIC 65HM-100/235-(72A)ER

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 100 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Burner head: heat-resistant
    • Constr. stage E
    • For annular excess air burner housing
  • BIC 65HB-200/235-(34)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage E
  • BIC 65HBR-200/235-(108)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • Reduced capacity (BIC: ceramic tube selction acc. brochure)
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 108
    • Constr. stage E
  • BIC 65HD-200/235-(98)F

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For town gas
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 98
    • Constr. stage F
  • BIC 65HM-200/235-(72)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Constr. stage E
  • BIC 65RB-200/235-(37)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage E
  • BIC 65RD-200/235-(38)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For town gas
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 38
    • Constr. stage E
  • BIC 65RM-200/235-(71)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For propane, propane/butane, butane (with mixer)
    • 200 mm steel tube from furnace flange
    • 235 mm furnace flange-front edge of burner disk
    • Code of burner head 71
    • Constr. stage E
  • BICA 65HB-400/435-(34)D

    Burner for gas, with aluminium housing
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Constr. stage D
  • BICA 65HM-400/435-(72)D

    Burner for gas, with aluminium housing
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Constr. stage D
  • BICA 65RB-400/435-(37)D

    Burner for gas, with aluminium housing
    • Burner size 65
    • Short flame shape
    • For natural gas
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 37
    • Constr. stage D
  • BICA 65RM-400/435-(71)D

    Burner for gas, with aluminium housing
    • Burner size 65
    • Short flame shape
    • For propane, propane/butane, butane (with mixer)
    • 400 mm steel tube from furnace flange
    • 435 mm furnace flange-front edge of burner disk
    • Code of burner head 71
    • Constr. stage D
  • BIC 65HBL-0/35-(86)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • Lance
    • 0 mm steel tube from furnace flange
    • 35 mm furnace flange-front edge of burner disk
    • Code of burner head 86
    • Constr. stage E
  • BIC 65HML-0/35-(106)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • Lance
    • 0 mm steel tube from furnace flange
    • 35 mm furnace flange-front edge of burner disk
    • Code of burner head 106
    • Constr. stage E
  • BICA 65HB-250/385-(34A)DR

    Burner for gas, with aluminium housing
    • Burner size 65
    • Longer flame shape
    • For natural gas
    • 250 mm steel tube from furnace flange
    • 385 mm furnace flange-front edge of burner disk
    • Code of burner head 34
    • Burner head: heat-resistant
    • Constr. stage D
    • For annular excess air burner housing
  • BICA 65HM-250/385-(72A)DR

    Burner for gas, with aluminium housing
    • Burner size 65
    • Longer flame shape
    • For propane, propane/butane, butane (with mixer)
    • 250 mm steel tube from furnace flange
    • 385 mm furnace flange-front edge of burner disk
    • Code of burner head 72
    • Burner head: heat-resistant
    • Constr. stage D
    • For annular excess air burner housing
  • BIC 65RBL-0/35-(82)E

    Burner for gas, with connection for ceramic tube
    • Burner size 65
    • Short flame shape
    • For natural gas
    • Lance
    • 0 mm steel tube from furnace flange
    • 35 mm furnace flange-front edge of burner disk
    • Code of burner head 82
    • Constr. stage E
  • Látható: 1-60 / 101 összesen
    12
    Mutat oldalanként
    Rendezés:
    Top