ImageNameSummaryArajanlat
BCU 440-10/1W1GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-10/1W1GB

Burner control unit, series 400

BCU 440-10/1W3GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-10/1W3GB

Burner control unit, series 400

BCU 440-3/1R1GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-3/1R3GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-3/1R3GB

Burner control unit, series 400

BCU 440-3/1W1GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-3/1W1GB

Burner control unit, series 400

BCU 440-3/1W1GB

Burner control unit, series 400

BCU 440-3/1W2GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-3/1W3GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-3/1W3GB

Burner control unit, series 400

BCU 440-3/1W8GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-3/1WGB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-5/1R1GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-5/1R3GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-5/1R3GB

Burner control unit, series 400

BCU 440-5/1R3GB

Burner control unit, series 400

BCU 440-5/1W1GB

Burner control unit, series 400

BCU 440-5/1W1GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-5/1W2GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-5/1W3GB

For controlling, igniting and monitoring gas burners in continuous operation, in metal housing, plug-in flange plate, adjustable with BCSoft, EC type-tested and certified, AGA approved, certified for systems up to SIL 3 from July 2012 (compliant with PL e).

BCU 440-5/1W3GB

Burner control unit, series 400

BCU 440-5/1W3GB

Burner control unit, series 400

BCU 440-5/1W3GB

Burner control unit, series 400

BCU 440-5/1W3GB

Burner control unit, series 400

IFW 15-N

For multi-flame control with IFS 110/111IM, for intermittent operation

IFW 15-T

For multi-flame control with IFS 110/111IM, for intermittent operation

IFW 50W/R

For multi-flame control with IFD 450/454, ionization control

MPT 700A

For converting a controller signal to switch-on/switch-off times for gas burners in the case of intermittant operation, linear response between actuating signal and burner capacity, control of up to 8 burners, various operating modes

PFA 700N

For interworking of up to nine automatic burner control units PFU 760 using PROFIBUS DP. The PFA 700 is integrated in the ready-wired module subrack BGT. The field bus interface PFA 700, together with the module subrack BGT, complies with the Low Voltage Directive (2006/95/EC) and the EMC Directive (2004/108/EC). Integrated power supply for the bus interface and the inputs of the automatic burner control units, Coding switches for addressing the field bus interface,

PFA 700N with PROFIBUS plug

For interworking of up to nine automatic burner control units PFU 760 using PROFIBUS DP. The PFA 700 is integrated in the ready-wired module subrack BGT. The field bus interface PFA 700, together with the module subrack BGT, complies with the Low Voltage Directive (2006/95/EC) and the EMC Directive (2004/108/EC). Integrated power supply for the bus interface and the inputs of the automatic burner control units, Coding switches for addressing the field bus interface,

PFA 700T

For interworking of up to nine automatic burner control units PFU 760 using PROFIBUS DP. The PFA 700 is integrated in the ready-wired module subrack BGT. The field bus interface PFA 700, together with the module subrack BGT, complies with the Low Voltage Directive (2006/95/EC) and the EMC Directive (2004/108/EC). Integrated power supply for the bus interface and the inputs of the automatic burner control units, Coding switches for addressing the field bus interface,

PFA 710N

For interworking of up to eight automatic burner control units PFU 780 using PROFIBUS DP. The PFA 710 is integrated in the ready-wired module subrack BGT. The field bus interface PFA 710, together with the module subrack BGT, complies with the Low Voltage Directive (2006/95/EC) and the EMC Directive (2004/108/EC). Integrated power supply for the bus interface and the inputs of the automatic burner control units, Coding switches for addressing the field bus interface,

PFA 710T

For interworking of up to eight automatic burner control units PFU 780 using PROFIBUS DP. The PFA 710 is integrated in the ready-wired module subrack BGT. The field bus interface PFA 710, together with the module subrack BGT, complies with the Low Voltage Directive (2006/95/EC) and the EMC Directive (2004/108/EC). Integrated power supply for the bus interface and the inputs of the automatic burner control units, Coding switches for addressing the field bus interface,

PFF 704T/N

For flame detection and for multi-flame detection with PFS/PFD

PFP 700T/N

To supply control inputs on the burner control unit PFS/PFD

PFR 704T/N/K/H

For isolated signal coupling

PFU 760LND