KépNévÖsszefoglalóArajanlat
Adapter set BIC 100T-LB
Adapter set BIC 140T-LB
Adapter set BIC 80T-LB
BIC 100HB-0/35-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-100/135-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-100/135-(37E)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Burner head: high temperature version with purged electrodes
  • Constr. stage E
BIC 100HB-1200/1235-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 1200 mm steel tube from furnace flange
  • 1235 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-150/185-(37E)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Burner head: high temperature version with purged electrodes
  • Constr. stage E
BIC 100HB-200/235-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-250/285-(37)ER
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
  • For annular excess air burner housing
BIC 100HB-300/335-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-300/335-(37E)ER
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Burner head: high temperature version with purged electrodes
  • Constr. stage E
  • For annular excess air burner housing
BIC 100HB-400/435-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-400/435-(37)EB
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
  • With secondary air holes
BIC 100HB-450/485-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 450 mm steel tube from furnace flange
  • 485 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-500/535-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 500 mm steel tube from furnace flange
  • 535 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-600/635-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 600 mm steel tube from furnace flange
  • 635 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HB-750/785-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 750 mm steel tube from furnace flange
  • 785 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 100HBL-0/35-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 100HBL-0/35-(49A)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Burner head: heat-resistant
  • Constr. stage E
BIC 100HBL-100/135-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 100HBL-200/235-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 100HBL-300/335-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 100HBL-400/435-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 100HD-0/35-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIC 100HD-100/135-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIC 100HD-200/235-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIC 100HD-300/335-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIC 100HD-400/435-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIC 100HLR-0/35-(119)D
  • Burner size 100
  • Longer flame shape
  • For low-caloric gas
  • Reduced capacity (BIC: ceramic tube selction acc. brochure)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 119
  • Constr. stage D
BIC 100HM-0/35-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIC 100HM-100/135-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIC 100HM-200/235-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIC 100HM-300/335-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIC 100HM-300/435-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIC 100HM-400/435-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIC 100HML-0/35-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIC 100HML-100/135-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIC 100HML-200/235-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIC 100HML-300/335-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIC 100MB-0/35-(118)E
  • Burner size 100
  • For low NOx operation menox
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 118
  • Constr. stage E
BIC 100RB-0/35-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-100/135-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-1000/1035-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 1000 mm steel tube from furnace flange
  • 1035 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-1000/1035-(70)EB
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 1000 mm steel tube from furnace flange
  • 1035 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
  • With secondary air holes
BIC 100RB-1200/1235-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 1200 mm steel tube from furnace flange
  • 1235 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-150/185-(109)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 109
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RB-200/235-(109)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 109
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RB-200/235-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-200/235-(70)EB
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
  • With secondary air holes
BIC 100RB-250/285-(109)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 109
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RB-300/335-(109)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 109
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RB-300/335-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-350/385-(109)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 350 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 109
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RB-400/435-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-500/535-(109)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 500 mm steel tube from furnace flange
  • 535 mm furnace flange-front edge of burner disk
  • Code of burner head 109
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RB-500/535-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 500 mm steel tube from furnace flange
  • 535 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-500/535-(70)EB
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 500 mm steel tube from furnace flange
  • 535 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
  • With secondary air holes
BIC 100RB-600/635-(109)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 600 mm steel tube from furnace flange
  • 635 mm furnace flange-front edge of burner disk
  • Code of burner head 109
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RB-600/635-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 600 mm steel tube from furnace flange
  • 635 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-600/635-(70)EP
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 600 mm steel tube from furnace flange
  • 635 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
  • For pot burner housing
BIC 100RB-700/735-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 700 mm steel tube from furnace flange
  • 735 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-800/835-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 800 mm steel tube from furnace flange
  • 835 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIC 100RB-800/835-(70)EP
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 800 mm steel tube from furnace flange
  • 835 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
  • For pot burner housing
BIC 100RB-900/935-(70)EB
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 900 mm steel tube from furnace flange
  • 935 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
  • With secondary air holes
BIC 100RBL-0/35-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 100RBL-100/135-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 100RBL-150/185-(111)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 111
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RBL-200/235-(111)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 111
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RBL-200/235-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 100RBL-250/285-(111)FR
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 111
  • Constr. stage F
  • For annular excess air burner housing
BIC 100RBL-300/335-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 100RBL-400/435-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 100RBL-50/85-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 50 mm steel tube from furnace flange
  • 85 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 100RD-0/35-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIC 100RD-100/135-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIC 100RD-150/185-(39A)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Burner head: heat-resistant
  • Constr. stage E
BIC 100RD-200/235-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIC 100RD-300/335-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIC 100RD-400/435-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIC 100RG-150/185-(40)ER
  • Burner size 100
  • Short flame shape
  • For propane
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage E
  • For annular excess air burner housing
BIC 100RG-200/235-(40)ER
  • Burner size 100
  • Short flame shape
  • For propane
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage E
  • For annular excess air burner housing
BIC 100RG-250/285-(40)ER
  • Burner size 100
  • Short flame shape
  • For propane
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage E
  • For annular excess air burner housing
BIC 100RG-300/335-(40)ER
  • Burner size 100
  • Short flame shape
  • For propane
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage E
  • For annular excess air burner housing
BIC 100RG-350/385-(40)ER
  • Burner size 100
  • Short flame shape
  • For propane
  • 350 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage E
  • For annular excess air burner housing
BIC 100RGL-150/185-(77)ER
  • Burner size 100
  • Short flame shape
  • For propane
  • Lance
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 77
  • Constr. stage E
  • For annular excess air burner housing
BIC 100RGL-200/235-(77)ER
  • Burner size 100
  • Short flame shape
  • For propane
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 77
  • Constr. stage E
  • For annular excess air burner housing
BIC 100RGL-250/285-(77)ER
  • Burner size 100
  • Short flame shape
  • For propane
  • Lance
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 77
  • Constr. stage E
  • For annular excess air burner housing
BIC 100RM-0/35-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIC 100RM-100/135-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIC 100RM-200/235-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIC 100RM-300/335-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIC 100RM-400/435-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIC 100RML-0/35-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIC 100RML-100/135-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIC 100RML-200/235-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIC 100RML-300/335-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIC 100RML-400/435-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIC 100T-LB-0/60-(H01)
  • Burner size 100
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 60 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 100T-LB-100/160-(H01)
  • Burner size 100
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 160 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 100T-LB-200/260-(H01)
  • Burner size 100
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 260 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 100T-LB-300/360-(H01)
  • Burner size 100
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 360 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 100T-LB-400/460-(H01)
  • Burner size 100
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 460 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 125HB-0/35-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIC 125HB-100/135-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIC 125HB-150/185-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIC 125HB-200/235-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIC 125HB-300/335-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIC 125HB-400/435-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIC 125HB-900/935-(2)EB
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 900 mm steel tube from furnace flange
  • 935 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
  • With secondary air holes
BIC 125HBL-0/35-(9)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 9
  • Constr. stage E
BIC 125HBL-100/135-(9)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 9
  • Constr. stage E
BIC 125HBL-200/235-(9)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 9
  • Constr. stage E
BIC 125HBL-300/335-(9)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 9
  • Constr. stage E
BIC 125HBL-400/435-(9)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 9
  • Constr. stage E
BIC 125HD-0/35-(22)E
  • Burner size 125
  • Longer flame shape
  • For town gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 22
  • Constr. stage E
BIC 125HD-100/135-(22)E
  • Burner size 125
  • Longer flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 22
  • Constr. stage E
BIC 125HD-100/135-(22)EB
  • Burner size 125
  • Longer flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 22
  • Constr. stage E
  • With secondary air holes
BIC 125HD-200/235-(22)E
  • Burner size 125
  • Longer flame shape
  • For town gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 22
  • Constr. stage E
BIC 125HD-300/335-(22)E
  • Burner size 125
  • Longer flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 22
  • Constr. stage E
BIC 125HD-500/535-(22)E
  • Burner size 125
  • Longer flame shape
  • For town gas
  • 500 mm steel tube from furnace flange
  • 535 mm furnace flange-front edge of burner disk
  • Code of burner head 22
  • Constr. stage E
BIC 125HLR-0/35-(27)D
  • Burner size 125
  • Longer flame shape
  • For low-caloric gas
  • Reduced capacity (BIC: ceramic tube selction acc. brochure)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 27
  • Constr. stage D
BIC 125HM-0/35-(16)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage E
BIC 125HM-100/135-(16)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage E
BIC 125HM-200/235-(16)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage E
BIC 125HM-300/335-(16)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage E
BIC 125HM-400/435-(16)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage E
BIC 125HML-0/35-(19)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 19
  • Constr. stage E
BIC 125HML-100/135-(19)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 19
  • Constr. stage E
BIC 125HML-200/235-(19)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 19
  • Constr. stage E
BIC 125HML-300/335-(19)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 19
  • Constr. stage E
BIC 125HML-400/435-(19)E
  • Burner size 125
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 19
  • Constr. stage E
BIC 125MB-0/35-(26)E
  • Burner size 125
  • For low NOx operation menox
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 125RB-0/35-(15)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 15
  • Constr. stage E
BIC 125RB-100/135-(15)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 15
  • Constr. stage E
BIC 125RB-200/235-(15)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 15
  • Constr. stage E
BIC 125RB-300/335-(15)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 15
  • Constr. stage E
BIC 125RB-400/435-(15)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 15
  • Constr. stage E
BIC 125RBL-0/35-(17)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 17
  • Constr. stage E
BIC 125RBL-100/135-(17)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 17
  • Constr. stage E
BIC 125RBL-200/235-(17)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 17
  • Constr. stage E
BIC 125RBL-300/335-(17)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 17
  • Constr. stage E
BIC 125RBL-400/435-(17)E
  • Burner size 125
  • Short flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 17
  • Constr. stage E
BIC 125RM-0/35-(14)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 14
  • Constr. stage E
BIC 125RM-100/135-(14)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 14
  • Constr. stage E
BIC 125RM-200/235-(14)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 14
  • Constr. stage E
BIC 125RM-300/335-(14)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 14
  • Constr. stage E
BIC 125RM-400/435-(14)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 14
  • Constr. stage E
BIC 125RML-0/35-(18)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 18
  • Constr. stage E
BIC 125RML-100/135-(18)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 18
  • Constr. stage E
BIC 125RML-200/235-(18)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 18
  • Constr. stage E
BIC 125RML-300/335-(18)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 18
  • Constr. stage E
BIC 125RML-400/435-(18)E
  • Burner size 125
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 18
  • Constr. stage E
BIC 140HB-0/235-(26)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 140HB-0/35-(26)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 140HB-100/135-(26)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 140HB-200/235-(26)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 140HB-300/335-(26)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 140HB-350/385-(26)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 350 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 140HB-400/435-(26)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 140HB-50/85-(26)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 50 mm steel tube from furnace flange
  • 85 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage E
BIC 140HBL-0/35-(44)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 44
  • Constr. stage E
BIC 140HBL-100/135-(44)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 44
  • Constr. stage E
BIC 140HBL-200/235-(44)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 44
  • Constr. stage E
BIC 140HBL-300/335-(44)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 44
  • Constr. stage E
BIC 140HBL-400/435-(44)E
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 44
  • Constr. stage E
BIC 140HD-0/335-(65)E
  • Burner size 140
  • Longer flame shape
  • For town gas
  • 0 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 65
  • Constr. stage E
BIC 140HD-0/35-(65)E
  • Burner size 140
  • Longer flame shape
  • For town gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 65
  • Constr. stage E
BIC 140HD-100/135-(65)E
  • Burner size 140
  • Longer flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 65
  • Constr. stage E
BIC 140HD-200/235-(65)E
  • Burner size 140
  • Longer flame shape
  • For town gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 65
  • Constr. stage E
BIC 140HLR-0/35-(76)D
  • Burner size 140
  • Longer flame shape
  • For low-caloric gas
  • Reduced capacity (BIC: ceramic tube selction acc. brochure)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 76
  • Constr. stage D
BIC 140HM-0/235-(52)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIC 140HM-0/335-(52)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIC 140HM-0/35-(52)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIC 140HM-100/135-(52)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIC 140HM-200/235-(52)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIC 140HM-300/335-(52)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIC 140HM-400/435-(52)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIC 140HML-0/35-(53)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 53
  • Constr. stage E
BIC 140HML-100/135-(53)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 53
  • Constr. stage E
BIC 140HML-200/235-(53)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 53
  • Constr. stage E
BIC 140HML-300/335-(53)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 53
  • Constr. stage E
BIC 140HML-400/435-(53)E
  • Burner size 140
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 53
  • Constr. stage E
BIC 140MB-0/35-(75)E
  • Burner size 140
  • For low NOx operation menox
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 75
  • Constr. stage E
BIC 140RB-0/35-(47)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 47
  • Constr. stage E
BIC 140RB-100/135-(47)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 47
  • Constr. stage E
BIC 140RB-200/235-(47)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 47
  • Constr. stage E
BIC 140RB-250/285-(47)ER
  • Burner size 140
  • Short flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 47
  • Constr. stage E
  • For annular excess air burner housing
BIC 140RB-300/335-(47)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 47
  • Constr. stage E
BIC 140RB-400/435-(47)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 47
  • Constr. stage E
BIC 140RB-50/85-(47)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • 50 mm steel tube from furnace flange
  • 85 mm furnace flange-front edge of burner disk
  • Code of burner head 47
  • Constr. stage E
BIC 140RBL-0/35-(54)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 54
  • Constr. stage E
BIC 140RBL-100/135-(54)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 54
  • Constr. stage E
BIC 140RBL-200/235-(54)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 54
  • Constr. stage E
BIC 140RBL-250/285-(54)ER
  • Burner size 140
  • Short flame shape
  • For natural gas
  • Lance
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 54
  • Constr. stage E
  • For annular excess air burner housing
BIC 140RBL-300/335-(54)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 54
  • Constr. stage E
BIC 140RBL-400/435-(54)E
  • Burner size 140
  • Short flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 54
  • Constr. stage E
BIC 140RM-0/35-(48)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 48
  • Constr. stage E
BIC 140RM-100/135-(48)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 48
  • Constr. stage E
BIC 140RM-200/235-(48)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 48
  • Constr. stage E
BIC 140RM-250/285-(48)ER
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 48
  • Constr. stage E
  • For annular excess air burner housing
BIC 140RM-300/335-(48)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 48
  • Constr. stage E
BIC 140RM-400/435-(48)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 48
  • Constr. stage E
BIC 140RML-0/35-(49)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 140RML-100/135-(49)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 140RML-200/235-(49)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 140RML-250/285-(49)ER
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
  • For annular excess air burner housing
BIC 140RML-300/335-(49)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 140RML-400/435-(49)E
  • Burner size 140
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIC 140T-LB-0/35-(H01)
  • Burner size 140
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 140T-LB-100/135-(H01)
  • Burner size 140
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 140T-LB-200/235-(H01)
  • Burner size 140
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 140T-LB-300/335-(H01)
  • Burner size 140
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 140T-LB-400/435-(H01)
  • Burner size 140
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 50HB-0/135-(37)D
  • Burner size 50
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BIC 50HB-0/35-(37)D
  • Burner size 50
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BIC 50HB-100/135-(37)D
  • Burner size 50
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BIC 50HB-100/135-(37A)D
  • Burner size 50
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Burner head: heat-resistant
  • Constr. stage D
BIC 50HB-100/235-(37)D
  • Burner size 50
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BIC 50HB-200/235-(37)D
  • Burner size 50
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BIC 50HB-300/335-(37)D
  • Burner size 50
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BIC 50HB-400/435-(37)D
  • Burner size 50
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BIC 50HG-0/35-(38)D
  • Burner size 50
  • Longer flame shape
  • For propane
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage D
BIC 50HG-100/135-(38)D
  • Burner size 50
  • Longer flame shape
  • For propane
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage D
BIC 50HG-200/235-(38)D
  • Burner size 50
  • Longer flame shape
  • For propane
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage D
BIC 50HG-300/335-(38)D
  • Burner size 50
  • Longer flame shape
  • For propane
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage D
BIC 50HG-400/435-(38)D
  • Burner size 50
  • Longer flame shape
  • For propane
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage D
BIC 50RB-0/35-(39)D
  • Burner size 50
  • Short flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage D
BIC 50RB-100/135-(39)D
  • Burner size 50
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage D
BIC 50RB-200/235-(39)D
  • Burner size 50
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage D
BIC 50RB-300/335-(39)D
  • Burner size 50
  • Short flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage D
BIC 50RB-400/435-(39)D
  • Burner size 50
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage D
BIC 50RG-0/35-(40)D
  • Burner size 50
  • Short flame shape
  • For propane
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage D
BIC 50RG-100/135-(40)D
  • Burner size 50
  • Short flame shape
  • For propane
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage D
BIC 50RG-200/235-(40)D
  • Burner size 50
  • Short flame shape
  • For propane
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage D
BIC 50RG-300/335-(40)D
  • Burner size 50
  • Short flame shape
  • For propane
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage D
BIC 50RG-400/435-(40)D
  • Burner size 50
  • Short flame shape
  • For propane
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 40
  • Constr. stage D
BIC 65HB-0/135-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-0/35-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-100/135-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-100/235-(34A)ER
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HB-150/285-(34A)ER
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HB-200/235-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-200/335-(34A)ER
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HB-250/385-(34A)ER
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HB-300/335-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-400/435-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-500/535-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 500 mm steel tube from furnace flange
  • 535 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-500/635-(34A)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 500 mm steel tube from furnace flange
  • 635 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage E
BIC 65HB-600/635-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 600 mm steel tube from furnace flange
  • 635 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-700/735-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 700 mm steel tube from furnace flange
  • 735 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-700/735-(34)EP
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 700 mm steel tube from furnace flange
  • 735 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
  • For pot burner housing
BIC 65HB-800/835-(34)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 800 mm steel tube from furnace flange
  • 835 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
BIC 65HB-900/935-(34)EP
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 900 mm steel tube from furnace flange
  • 935 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage E
  • For pot burner housing
BIC 65HBL-0/35-(86)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 65HBL-100/135-(86)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 65HBL-200/235-(86)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 65HBL-300/335-(86)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 65HBL-400/435-(86)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIC 65HBR-200/235-(108)E
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • Reduced capacity (BIC: ceramic tube selction acc. brochure)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 108
  • Constr. stage E
BIC 65HD-0/35-(98)F
  • Burner size 65
  • Longer flame shape
  • For town gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 98
  • Constr. stage F
BIC 65HD-100/135-(98)F
  • Burner size 65
  • Longer flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 98
  • Constr. stage F
BIC 65HD-200/235-(98)F
  • Burner size 65
  • Longer flame shape
  • For town gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 98
  • Constr. stage F
BIC 65HD-300/335-(98)F
  • Burner size 65
  • Longer flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 98
  • Constr. stage F
BIC 65HD-400/435-(98)F
  • Burner size 65
  • Longer flame shape
  • For town gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 98
  • Constr. stage F
BIC 65HLR-0/35-(103)D
  • Burner size 65
  • Longer flame shape
  • For low-caloric gas
  • Reduced capacity (BIC: ceramic tube selction acc. brochure)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 103
  • Constr. stage D
BIC 65HM-0/35-(72)E
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage E
BIC 65HM-100/135-(72)E
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage E
BIC 65HM-100/235-(72A)ER
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HM-150/285-(72A)ER
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 150 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HM-200/235-(72)E
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage E
BIC 65HM-200/335-(72A)ER
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HM-250/385-(72A)ER
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 250 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HM-300/335-(72)E
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage E
BIC 65HM-350/485-(72A)ER
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 350 mm steel tube from furnace flange
  • 485 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage E
  • For annular excess air burner housing
BIC 65HM-400/435-(72)E
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage E
BIC 65HML-0/35-(106)E
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 106
  • Constr. stage E
BIC 65MB-0/35-(104)E
  • Burner size 65
  • For low NOx operation menox
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 104
  • Constr. stage E
BIC 65RB-0/35-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-0/35-(37A)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Burner head: heat-resistant
  • Constr. stage E
BIC 65RB-100/135-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-100/135-(37)EB
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
  • With secondary air holes
BIC 65RB-1000/1035-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 1000 mm steel tube from furnace flange
  • 1035 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-200/235-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-300/335-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-350/385-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 350 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-400/435-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-400/435-(37)EB
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
  • With secondary air holes
BIC 65RB-550/585-(37)EP
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 550 mm steel tube from furnace flange
  • 585 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
  • For pot burner housing
BIC 65RB-600/635-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 600 mm steel tube from furnace flange
  • 635 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-700/735-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 700 mm steel tube from furnace flange
  • 735 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RB-800/835-(37)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 800 mm steel tube from furnace flange
  • 835 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIC 65RBL-0/35-(82)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 82
  • Constr. stage E
BIC 65RBL-200/235-(82)E
  • Burner size 65
  • Short flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 82
  • Constr. stage E
BIC 65RD-0/35-(38)E
  • Burner size 65
  • Short flame shape
  • For town gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage E
BIC 65RD-100/135-(38)E
  • Burner size 65
  • Short flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage E
BIC 65RD-200/235-(38)E
  • Burner size 65
  • Short flame shape
  • For town gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage E
BIC 65RD-300/335-(38)E
  • Burner size 65
  • Short flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage E
BIC 65RD-400/435-(38)E
  • Burner size 65
  • Short flame shape
  • For town gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage E
BIC 65RM-0/35-(71)E
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIC 65RM-100/135-(71)E
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIC 65RM-200/235-(71)E
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIC 65RM-300/335-(71)E
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIC 65RM-400/435-(71)E
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIC 65RML-200/235-(83)E
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 83
  • Constr. stage E
BIC 80HB-0/35-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HB-100/135-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HB-150/185-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HB-150/185-(16E)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Burner head: high temperature version with purged electrodes
  • Constr. stage F
BIC 80HB-200/235-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HB-250/285-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HB-250/285-(16)FB
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
  • With secondary air holes
BIC 80HB-300/335-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HB-350/385-(16A)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 350 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Burner head: heat-resistant
  • Constr. stage F
BIC 80HB-400/435-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HB-400/435-(16)FB
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
  • With secondary air holes
BIC 80HB-50/85-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 50 mm steel tube from furnace flange
  • 85 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HB-650/685-(16)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • 650 mm steel tube from furnace flange
  • 685 mm furnace flange-front edge of burner disk
  • Code of burner head 16
  • Constr. stage F
BIC 80HBL-0/35-(34)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage F
BIC 80HBL-100/135-(34)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage F
BIC 80HBL-200/235-(34)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage F
BIC 80HBL-300/335-(34)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage F
BIC 80HBL-400/435-(34)F
  • Burner size 80
  • Longer flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage F
BIC 80HD-0/35-(51)E
  • Burner size 80
  • Longer flame shape
  • For town gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 51
  • Constr. stage E
BIC 80HD-100/135-(51)E
  • Burner size 80
  • Longer flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 51
  • Constr. stage E
BIC 80HD-200/235-(51)E
  • Burner size 80
  • Longer flame shape
  • For town gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 51
  • Constr. stage E
BIC 80HD-300/335-(51)E
  • Burner size 80
  • Longer flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 51
  • Constr. stage E
BIC 80HD-400/435-(51)E
  • Burner size 80
  • Longer flame shape
  • For town gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 51
  • Constr. stage E
BIC 80HLR-0/35-(56)D
  • Burner size 80
  • Longer flame shape
  • For low-caloric gas
  • Reduced capacity (BIC: ceramic tube selction acc. brochure)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 56
  • Constr. stage D
BIC 80HM-0/35-(35)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 35
  • Constr. stage F
BIC 80HM-100/135-(35)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 35
  • Constr. stage F
BIC 80HM-150/185-(35)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 35
  • Constr. stage F
BIC 80HM-200/235-(35)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 35
  • Constr. stage F
BIC 80HM-250/285-(35)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 35
  • Constr. stage F
BIC 80HM-300/335-(35)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 35
  • Constr. stage F
BIC 80HM-400/435-(35)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 35
  • Constr. stage F
BIC 80HM-50/85-(35)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 50 mm steel tube from furnace flange
  • 85 mm furnace flange-front edge of burner disk
  • Code of burner head 35
  • Constr. stage F
BIC 80HML-0/35-(38)F
  • Burner size 80
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 38
  • Constr. stage F
BIC 80MB-0/35-(57)E
  • Burner size 80
  • For low NOx operation menox
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 57
  • Constr. stage E
BIC 80MB-100/135-(57)E
  • Burner size 80
  • For low NOx operation menox
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 57
  • Constr. stage E
BIC 80RB-0/35-(6)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 6
  • Constr. stage E
BIC 80RB-100/135-(6)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 6
  • Constr. stage E
BIC 80RB-150/185-(6)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 6
  • Constr. stage E
BIC 80RB-200/235-(6)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 6
  • Constr. stage E
BIC 80RB-300/335-(6)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 6
  • Constr. stage E
BIC 80RB-400/435-(6)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 6
  • Constr. stage E
BIC 80RB-50/85-(6)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • 50 mm steel tube from furnace flange
  • 85 mm furnace flange-front edge of burner disk
  • Code of burner head 6
  • Constr. stage E
BIC 80RB-600/635-(6)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • 600 mm steel tube from furnace flange
  • 635 mm furnace flange-front edge of burner disk
  • Code of burner head 6
  • Constr. stage E
BIC 80RBL-0/35-(11)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • Lance
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 11
  • Constr. stage E
BIC 80RBL-100/135-(11)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 11
  • Constr. stage E
BIC 80RBL-200/235-(11)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 11
  • Constr. stage E
BIC 80RBL-300/335-(11)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 11
  • Constr. stage E
BIC 80RBL-400/435-(11)E
  • Burner size 80
  • Short flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 11
  • Constr. stage E
BIC 80RM-0/35-(12)E
  • Burner size 80
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 12
  • Constr. stage E
BIC 80RM-100/135-(12)E
  • Burner size 80
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 12
  • Constr. stage E
BIC 80RM-200/235-(12)E
  • Burner size 80
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 12
  • Constr. stage E
BIC 80RM-250/285-(12)E
  • Burner size 80
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 250 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 12
  • Constr. stage E
BIC 80RM-300/335-(12)E
  • Burner size 80
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 12
  • Constr. stage E
BIC 80RM-350/385-(12A)E
  • Burner size 80
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 350 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 12
  • Burner head: heat-resistant
  • Constr. stage E
BIC 80RM-400/435-(12)E
  • Burner size 80
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 12
  • Constr. stage E
BIC 80RML-300/335-(15)E
  • Burner size 80
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 15
  • Constr. stage E
BIC 80T-LB-0/35-(H01)
  • Burner size 80
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 80T-LB-100/135-(H01)
  • Burner size 80
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 80T-LB-200/235-(H01)
  • Burner size 80
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 80T-LB-300/335-(H01)
  • Burner size 80
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BIC 80T-LB-400/435-(H01)
  • Burner size 80
  • T-product
  • For high excess air and broad ignition range
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 1
BICA 65HB-0/135-(34)D
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage D
BICA 65HB-0/35-(34)D
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage D
BICA 65HB-100/135-(34)D
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage D
BICA 65HB-100/235-(34A)DR
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HB-150/285-(34A)DR
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HB-200/235-(34)D
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage D
BICA 65HB-200/335-(34A)DR
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HB-250/385-(34A)DR
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HB-300/335-(34)D
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage D
BICA 65HB-350/485-(34A)DR
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 350 mm steel tube from furnace flange
  • 485 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HB-400/435-(34)D
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage D
BICA 65HB-50/185-(34)D
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 50 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage D
BICA 65HB-550/685-(34A)DR
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 550 mm steel tube from furnace flange
  • 685 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HM-0/35-(72)D
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage D
BICA 65HM-100/135-(72)D
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage D
BICA 65HM-100/235-(72A)DR
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HM-150/285-(72A)DR
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 150 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HM-200/235-(72)D
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage D
BICA 65HM-200/335-(72A)DR
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HM-250/385-(72A)DR
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 250 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Burner head: heat-resistant
  • Constr. stage D
  • For annular excess air burner housing
BICA 65HM-300/335-(72)D
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage D
BICA 65HM-400/435-(72)D
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage D
BICA 65HM-50/185-(72)D
  • Burner size 65
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 50 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 72
  • Constr. stage D
BICA 65RB-0/35-(37)D
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BICA 65RB-100/135-(37)D
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BICA 65RB-200/235-(37)D
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BICA 65RB-300/335-(37)D
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BICA 65RB-400/435-(37)D
  • Burner size 65
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage D
BICA 65RM-0/35-(71)D
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 0 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage D
BICA 65RM-100/135-(71)D
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage D
BICA 65RM-200/235-(71)D
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage D
BICA 65RM-300/335-(71)D
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage D
BICA 65RM-400/435-(71)D
  • Burner size 65
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage D
BICW 100HB-100/135-(37)G
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage G
BICW 125HB-100/135-(2)F
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage F
BICW 140HB-100/135-(26)F
  • Burner size 140
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 26
  • Constr. stage F
BICW 65HB-100/135-(34)G
  • Burner size 65
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 34
  • Constr. stage G
BIO 100HB-100/35-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIO 100HB-100/35-(37A)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Burner head: heat-resistant
  • Constr. stage E
BIO 100HB-200/135-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIO 100HB-200/35-(37)EB
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
  • With secondary air holes
BIO 100HB-300/235-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIO 100HB-350/285-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 350 mm steel tube from furnace flange
  • 285 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIO 100HB-400/335-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIO 100HB-450/385-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 450 mm steel tube from furnace flange
  • 385 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIO 100HB-500/435-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 500 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIO 100HB-600/535-(37)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • 600 mm steel tube from furnace flange
  • 535 mm furnace flange-front edge of burner disk
  • Code of burner head 37
  • Constr. stage E
BIO 100HBL-100/35-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 100 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIO 100HBL-200/135-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 200 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIO 100HBL-300/235-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIO 100HBL-400/335-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 400 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIO 100HBL-500/435-(49)E
  • Burner size 100
  • Longer flame shape
  • For natural gas
  • Lance
  • 500 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 49
  • Constr. stage E
BIO 100HD-100/35-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 100 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIO 100HD-200/135-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 200 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIO 100HD-300/135-(115)FB
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
  • With secondary air holes
BIO 100HD-300/235-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIO 100HD-300/235-(115B)D
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 300 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Burner head: sulfur-resistant
  • Constr. stage D
BIO 100HD-400/335-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 400 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIO 100HD-500/435-(115)F
  • Burner size 100
  • Longer flame shape
  • For town gas
  • 500 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 115
  • Constr. stage F
BIO 100HM-100/35-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 100 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIO 100HM-200/135-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 200 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIO 100HM-300/235-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 300 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIO 100HM-400/235-(67)EB
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
  • With secondary air holes
BIO 100HM-400/335-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIO 100HM-500/435-(67)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • 500 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 67
  • Constr. stage E
BIO 100HML-100/35-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 100 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIO 100HML-200/135-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 200 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIO 100HML-300/235-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 300 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIO 100HML-400/235-(79)EB
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 400 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
  • With secondary air holes
BIO 100HML-400/335-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 400 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIO 100HML-500/435-(79)E
  • Burner size 100
  • Longer flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 500 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 79
  • Constr. stage E
BIO 100KB-150/135-(41)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 41
  • Constr. stage E
BIO 100KB-150/135-(41E)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 41
  • Burner head: high temperature version with purged electrodes
  • Constr. stage E
BIO 100KB-200/185-(41E)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 41
  • Burner head: high temperature version with purged electrodes
  • Constr. stage E
BIO 100KB-250/235-(41)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 41
  • Constr. stage E
BIO 100KB-250/235-(41E)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 41
  • Burner head: high temperature version with purged electrodes
  • Constr. stage E
BIO 100KB-350/335-(41)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 41
  • Constr. stage E
BIO 100KB-450/435-(41)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 41
  • Constr. stage E
BIO 100KB-50/35-(41)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 41
  • Constr. stage E
BIO 100KBL-150/135-(52)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • Lance
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIO 100KBL-250/235-(52)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • Lance
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIO 100KBL-350/335-(52)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • Lance
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIO 100KBL-450/435-(52)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • Lance
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIO 100KBL-50/35-(52)E
  • Burner size 100
  • Flat flame shape
  • For natural gas
  • Lance
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 52
  • Constr. stage E
BIO 100KD-150/135-(71)E
  • Burner size 100
  • Flat flame shape
  • For town gas
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIO 100KD-250/235-(71)E
  • Burner size 100
  • Flat flame shape
  • For town gas
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIO 100KD-350/335-(71)E
  • Burner size 100
  • Flat flame shape
  • For town gas
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIO 100KD-450/435-(71)E
  • Burner size 100
  • Flat flame shape
  • For town gas
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIO 100KD-50/35-(71)E
  • Burner size 100
  • Flat flame shape
  • For town gas
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 71
  • Constr. stage E
BIO 100KM-150/135-(84)E
  • Burner size 100
  • Flat flame shape
  • For propane, propane/butane, butane (with mixer)
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 84
  • Constr. stage E
BIO 100KM-250/235-(84)E
  • Burner size 100
  • Flat flame shape
  • For propane, propane/butane, butane (with mixer)
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 84
  • Constr. stage E
BIO 100KM-350/335-(84)E
  • Burner size 100
  • Flat flame shape
  • For propane, propane/butane, butane (with mixer)
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 84
  • Constr. stage E
BIO 100KM-450/435-(84)E
  • Burner size 100
  • Flat flame shape
  • For propane, propane/butane, butane (with mixer)
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 84
  • Constr. stage E
BIO 100KM-50/35-(84)E
  • Burner size 100
  • Flat flame shape
  • For propane, propane/butane, butane (with mixer)
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 84
  • Constr. stage E
BIO 100KML-50/35-(117)E
  • Burner size 100
  • Flat flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 117
  • Constr. stage E
BIO 100RB-100/85-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 85 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIO 100RB-150/135-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIO 100RB-200/135-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIO 100RB-200/185-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIO 100RB-250/235-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIO 100RB-350/335-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIO 100RB-400/235-(70)EB
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 400 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
  • With secondary air holes
BIO 100RB-450/435-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIO 100RB-50/35-(70)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 70
  • Constr. stage E
BIO 100RBL-150/135-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIO 100RBL-250/235-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIO 100RBL-300/135-(86)EB
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 300 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
  • With secondary air holes
BIO 100RBL-350/335-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIO 100RBL-450/435-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIO 100RBL-50/35-(86)E
  • Burner size 100
  • Short flame shape
  • For natural gas
  • Lance
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 86
  • Constr. stage E
BIO 100RD-150/135-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIO 100RD-250/235-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIO 100RD-350/335-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIO 100RD-450/435-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIO 100RD-50/35-(39)E
  • Burner size 100
  • Short flame shape
  • For town gas
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 39
  • Constr. stage E
BIO 100RGL-150/135-(77)E
  • Burner size 100
  • Short flame shape
  • For propane
  • Lance
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 77
  • Constr. stage E
BIO 100RM-150/135-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIO 100RM-250/235-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIO 100RM-350/335-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIO 100RM-400/235-(85)EB
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 400 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
  • With secondary air holes
BIO 100RM-450/435-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIO 100RM-50/35-(85)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 85
  • Constr. stage E
BIO 100RML-150/135-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 150 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIO 100RML-250/235-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 250 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIO 100RML-350/335-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 350 mm steel tube from furnace flange
  • 335 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIO 100RML-450/435-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 450 mm steel tube from furnace flange
  • 435 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIO 100RML-50/35-(87)E
  • Burner size 100
  • Short flame shape
  • For propane, propane/butane, butane (with mixer)
  • Lance
  • 50 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 87
  • Constr. stage E
BIO 125HB-100/35-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 100 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIO 125HB-1100/1035-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 1100 mm steel tube from furnace flange
  • 1035 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIO 125HB-150/85-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 150 mm steel tube from furnace flange
  • 85 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIO 125HB-200/135-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 200 mm steel tube from furnace flange
  • 135 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIO 125HB-250/185-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 185 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
BIO 125HB-250/35-(2)EB
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 250 mm steel tube from furnace flange
  • 35 mm furnace flange-front edge of burner disk
  • Code of burner head 2
  • Constr. stage E
  • With secondary air holes
BIO 125HB-300/235-(2)E
  • Burner size 125
  • Longer flame shape
  • For natural gas
  • 300 mm steel tube from furnace flange
  • 235 mm furnace flange-front edge of burner disk
  • Code of burner head 2